@air
2025-07-03

Standard for compressed air in the semiconductor industry

The semiconductor industry has extremely strict quality requirements for compressed air and needs to meet a number of core standards to ensure product quality and production stability. The following is explained from three aspects: key parameters, system design and management specifications:

1. Core quality standards

1. Particulate matter control

  • cleanliness level: It must meet Level 5 or higher in the ISO 14644-1 standard, that is, the number of particles ≥0.1 micron per cubic meter of air does not exceed 10000. Precision equipment such as lithography machines may require more stringent Class 100 clean room standards (≤3520 units/cubic meter).
  • control significance: Particles may scratch the wafer or contaminate optical components, causing product defects.

2. humidity control

  • dew point temperature: Generally, it is required to be below-40℃, and high-end processes may require below-70℃, corresponding to a water content of only tens of ppm.
  • control significance: Prevent condensed water from causing equipment corrosion, circuit short circuits or product contamination.

3. Oil content control

  • limit value: The total oil content needs to be less than 0.01mg/m³, which is close to oil-free.
  • control significance: Avoid oil contamination of sensitive components or affecting the thin film deposition process.

4. Chemical pollutant control

  • prohibited ingredients: Do not contain acidic substances, alkaline substances, ammonia, sulfides and other corrosive or polluting substances.
  • control significance: Prevent chemical pollutants from causing wafer surface defects or equipment corrosion.

5. microbial control

  • special requirements: In aseptic packaging and other aspects, the microbial concentration needs to be controlled through high-efficiency filtration and ultraviolet sterilization.
  • control significance: Avoid the growth of microorganisms and affect product yield.

2. System design and equipment requirements

1. Compressed air treatment process

  • typical configuration: Air compressor → buffer tank → aftercooler → multi-stage filter (dust removal and oil removal) → dryer (adsorption type or freezing type) → terminal filter → gas point.
  • key equipment
    • dryer: The adsorption dryer can achieve a dew point of-70℃, and the freezing dryer is suitable for general needs.
    • filter: A high-efficiency filter needs to be used, and the filtration efficiency of 0.01 micron particles reaches 99.999%.

2. Pipeline and Storage

  • material requirements: The main pipe is made of 304L or 316L stainless steel, which needs to be pickled and passivated after welding, and the inner wall roughness is ≤0.8μm.
  • layout specification: The slope of the pipeline is ≥1%, and a drainage valve is set every 30 meters to avoid the accumulation of condensate.

3. Pressure and flow stability

  • pressure control: It needs to be stable within the equipment requirements (such as 0.5-0.7MPa), and the fluctuation range is ≤±0.05MPa.
  • flow assurance: Dynamic adjustment is achieved through air storage tank capacity optimization (it is recommended to meet the 30-minute air consumption) and inverter compressor.

3. Operation management specifications

1. monitoring and measurement

  • on-line monitoring: Install particle counters, dew point meters, and oil detectors to monitor air quality in real time.
  • regular testing: Entrust a third-party agency to conduct all tests, including chemical pollutants and microorganisms, every quarter.

2. maintenance

  • filter replacement: Replace the filter element every 3-6 months according to the differential pressure indicator.
  • drier regenerant: Adsorption dryers need to replace molecular sieves regularly, and freezing dryers need to clean the condenser.
  • pipeline cleaning: Carry out compressed air purging once a year to remove attachments on the inner wall of the pipeline.

3. Emergency Management

  • standby equipment: Configure redundant air compressors and dryers to ensure that single points of failure do not affect production.
  • Handling of abnormal pressure: When the pressure fluctuation exceeds the limit, the system automatically switches to the standby air source and triggers an alarm.

4. Industry application differences

application scenarios particulate requirement Dew point requirements typical equipment
photolithography process ≤0.1μm, 10000 pieces/m³ ≤-70℃ ABM lithography machine, ASML scanner
etching process ≤0.3μm, 100000 pieces/m³ ≤-40℃ LAM etching machine, TEL cleaning equipment
packaging and testing ≤1μm, 1000000 pieces/m³ ≤-20℃ Mounter, test sorting machine

V. Summary

The semiconductor industry compressed air standard is the cornerstone of quality control and needs to be achieved through precise system design, strict equipment selection and standardized operation management. Enterprises should establish a full-process quality control system from the outlet of the air compressor to the point of gas consumption, and formulate internal specifications in conjunction with ISO 8573 or GB/T 13277 standards to ensure that the quality of compressed air meets the strict requirements of semiconductor processes.

Welcome!

Related Articles:
@air
2025-03-07

Do I need to refuel the silent air compressor?

Whether a silent air compressor needs to be refueled depends on its type. Silent oil-free air compressor does not require refueling. This type of air compressor uses oil-free lubrication technology, and internal moving parts do not need to rely on lubricating oil for lubrication. Its working principle is to compress it through self-lubricating pistons or […]

@air
2025-05-12

What is the general pressure of factory gas

Professional instructions on the standard range of factory gas pressure factory gas pressure needs to be comprehensively determined based on production process, equipment characteristics and safety regulations. There is no globally unified fixed value. Now we provide professional analysis from technical standards, industry practices and optimization directions…

@air
2025-12-16

Requirements for compressed air levels for food production enterprises

In food production enterprises, the grade requirements for compressed air need to be classified according to its contact mode with the food (direct contact, indirect contact or non-contact), and must meet international standards (such as ISO 8573-1:2010) and industry regulations…

@air
2025-08-20

What does air compressor 0.8mpa and 0.2mpa mean?

The 0.8MPa and 0.2MPa marked on the air compressor refer to the pressure level of the compressed air output by the equipment (MPa is MPa, 1MPa≈10 kg force/square centimeter). These two values represent what the air compressor can stably provide…

@air
2025-04-21

What is a medical-grade clean air source

Medical-grade clean air source, simply put, is compressed air that meets the special requirements of the medical and pharmaceutical industries. It mainly needs to meet the conditions of high purity, no oil, no water, no impurities, and even sterility. In the medical and pharmaceutical industries, things like driving surgical instruments,…