@air
2025-09-03

How often should the air compressor filter be cleaned?

Air compressor filter cleaning cycle recommendations
The cleaning frequency of air compressor filters needs to be flexibly adjusted based on actual use scenarios. The core principle isThrough regular inspections and equipment operating status monitoring rather than fixed time periods。The following are specific suggestions:

1. analysis of influencing factors

  • use environment: If there is too much dust in the workshop (such as metal processing, wood processing), the filter will easily be blocked, and the inspection interval needs to be shortened; if the environment is clean (such as electronic component assembly), it can be extended appropriately.
  • equipment load: When the air compressor is running continuously at high load, the filter pollution rate will increase, and the frequency of inspections will need to be increased.
  • filter type: The cleaning cycles of primary filters (which intercept large particles) and precision filters (which filter micron impurities) are different and require separate attention.

2. Practical judgment method

  • observe the pressure gauge: If the exhaust pressure of the air compressor drops significantly (such as from 0.8MPa to 0.6MPa), the air pressure may be lost due to clogging of the filter, which requires immediate cleaning.
  • Listen to abnormal sounds: When the filter is severely blocked, the operating noise of the air compressor may increase or be accompanied by abnormal vibration.
  • Regular visual inspection: It is recommended to disassemble the filter housing every 200-300 hours of operation (about 1 month) to observe the accumulation of pollutants on the surface of the filter element.

3. Adaptability recommendations for Granklin air compressors
Granklin’s water-lubricated single-screw air compressor adopts oil-free technology. The compressed air does not contain oil. Therefore, the filter mainly intercepts dust, moisture or metal particles, and the source of pollution is relatively single. Users can focus on the following scenarios:

  • High dust environment: It is recommended to check the primary filter every 150 hours and reverse purge with compressed air if necessary (note that the air pressure does not exceed 0.2MPa to avoid damaging the filter material).
  • humid environment: The drainage device needs to be checked regularly to avoid moisture accumulating in the filter, causing moisture to deform the filter element.
  • Precision filtration needs: If it is used in the spraying or electronics industry, it is recommended to replace the precision filter element every 500 hours to ensure the purity of the compressed air.

conclusion
There is no fixed standard for the cleaning cycle of air compressor filters and needs to be passed.Pressure monitoring, visual inspection and environmental assessmentComprehensive judgment. Due to its oil-free design, Granklin water-lubricated single-screw air compressor can reduce oil pollution, but the inspection frequency needs to be adjusted according to actual use scenarios to ensure stable operation of the equipment and cleanliness of compressed air.

Welcome!

Related Articles:
@air
2025-08-19

Why does the air compressor use 0.8MPa instead of 1.0MPa?

The air compressor adopts a pressure setting of 0.8MPa instead of 1.0MPa, which is mainly based on comprehensive considerations of actual application needs, operating efficiency and cost: 1. Covering mainstream industrial scenarios, the pressure level of 0.8MPa can meet the greatest…

@air
2025-07-30

How much redundancy is generally considered for air compressors

In the design of air compressor systems, redundant configuration needs to be scientifically planned based on actual use scenarios and needs. Granklin water-lubricated single-screw air compressor adopts a compression structure combined with a single screw and a star wheel, which has the characteristics of simple structure and stable operation….

@air
2025-04-10

What is hospital compressed air for?

The hospital’s compressed air system supports the entire process of medical needs from first aid to disinfection by providing a clean and stable air source. Its design and quality control standards are much higher than those in industrial scenarios, which are directly related to the safety of patients ‘lives and are the key lifeline of the operation of modern hospitals.

@air
2025-06-11

Can the air compressor be equipped with an automatic drain?

Air compressors can be equipped with automatic drainers, a configuration that has been widely used in the industrial field. The following is a detailed explanation from three aspects: compatibility, functional functions and installation advantages: 1. Compatibility analysis Automatic drainers and air compressors…

@air
2025-04-17

Air compressor maintenance depends on running time or load time

The determination of the air compressor maintenance cycle needs to consider both the operating time and the load time, but which is the main one needs to be combined with the equipment type, working conditions and manufacturer specifications. The following is a detailed analysis: 1. The definition and role of running time and load time. Operation…