Air compressor usage method

Standardized use of air compressors is the key to ensuring equipment performance and extending service life. Through innovative design, Granklin water-lubricated single screw air compressor provides users with a simple and safe operating experience. For specific use methods, please refer to the following steps:

1. Preparation before launch

  1. Check the equipment installation environment to ensure good ventilation and stay away from flammable and explosive materials.
  2. Make sure that the power supply connection meets the rated voltage of the equipment and that there is no leakage at the water pipe interface.
  3. Open the drain valve to drain the residual moisture in the air storage tank to prevent compressed air from carrying water and affecting use.

2. Start-up and operation

  1. Press the start button to enter the automatic operation state, and observe that the pressure gauge value gradually increases to the set range (usually 0.6-0.8MPa).
  2. After first use or long-term shutdown, it is recommended to run without load for 5-10 minutes, confirm that there is no abnormal vibration or noise before loading it for use.
  3. During operation, the exhaust pressure can be adjusted through the control panel to meet the needs of different gas consumption scenarios.

3. Shutdown operation

  1. Before turning off the equipment, switch the load to the no-load state through the control panel to avoid shutdown under pressure.
  2. Press the stop button and the equipment will automatically stop after completing the internal cleaning procedure.
  3. Open the drain valve to drain the compressed air and condensed water in the air storage tank to prevent corrosion of the pipeline.

4. Daily maintenance

  1. Waterway inspection: Regularly confirm that the water supply to the water lubrication system is sufficient and that the water quality cleanliness meets the requirements (it is recommended to use softened water or purified water).
  2. Filter cleaning: Check the air inlet filter every 500 hours to remove surface dust and maintain smooth air circulation.
  3. drainage management: Drain the condensed water from the air storage tank daily or weekly depending on the frequency of use to avoid moisture accumulation and affecting air quality.
  4. Appearance maintenance: Keep the surface of the equipment clean and wipe the heat sinks regularly to ensure heat dissipation efficiency.

5. Safety precautions

  1. Never open the protective cover or touch rotating parts while the equipment is in operation.
  2. During repair or maintenance, it is necessary to cut off the power supply and release the pressure in the air tank.
  3. If abnormal vibration, water leakage or pressure fluctuations are found, stop the machine immediately and contact professional personnel for maintenance.

Through oil-free design and intelligent control system, Granklin water-lubricated single-screw air compressor simplifies the complex oil maintenance process of traditional air compressors. Users only need to pay attention to waterway supply and basic cleaning to achieve efficient and stable compressed air supply. This feature makes it an ideal choice for combining operational convenience and operational reliability in industries such as medicine, food, and electronics that require strict air cleanliness.

Welcome!

Related Articles:
@air
2025-08-20

What are the uses of air compressors in medical gases

The application of air compressors in the medical field mainly involves providing stable and clean power source for various medical equipment. Thanks to its oil-free compression characteristics and reliable performance, Granklin water-lubricated single-screw air compressor can adapt to the needs of a variety of medical scenarios: 1. Breathe…

@air
2025-07-09

How big an air compressor is needed for a 200-ton pure water filling line per day

In the planning of a 200-ton pure water filling production line per day, the selection of air compressors needs to comprehensively consider the demand for air equipment, air pressure stability, air cleanliness and energy efficiency performance. The following are the analysis of key technical parameters and equipment configuration suggestions: 1…

@air
2025-03-24

Lubricating method of oilless air compressor

The lubrication method of oilless air compressor integrates multi-field technologies such as material science and fluid mechanics. Through innovative designs such as self-lubricating materials, water lubrication, air lubrication and packaging lubrication, it ensures the purity of compressed air while taking into account high efficiency, advantages of environmental protection and low maintenance costs. This combination of technologies makes it an irreplaceable critical device in industries with stringent air quality requirements.

@air
2025-03-09

There is no water in the air compressor to drain

When water cannot be discharged from the air compressor, the possible reasons and solutions are as follows: Possible causes The humidity in the air is too high: The air always contains a certain amount of moisture, that is, humidity. When the air is compressed, these moisture will reach a supersaturation state and precipitate into liquid. […]

@air
2025-03-12

How to deal with water in the air pipe in the air compressor system

When there is water in the air pipe of the air compressor system, the following measures can be taken to deal with it: 1. Drain in time Check and open the drain valve: The drain valve is usually provided at the bottom of the cooler of the air compressor. The drain valve should be checked […]