@air
2025-07-25

Air compressor usage method

Standardized use of air compressors is the key to ensuring equipment performance and extending service life. Through innovative design, Granklin water-lubricated single screw air compressor provides users with a simple and safe operating experience. For specific use methods, please refer to the following steps:

1. Preparation before launch

  1. Check the equipment installation environment to ensure good ventilation and stay away from flammable and explosive materials.
  2. Make sure that the power supply connection meets the rated voltage of the equipment and that there is no leakage at the water pipe interface.
  3. Open the drain valve to drain the residual moisture in the air storage tank to prevent compressed air from carrying water and affecting use.

2. Start-up and operation

  1. Press the start button to enter the automatic operation state, and observe that the pressure gauge value gradually increases to the set range (usually 0.6-0.8MPa).
  2. After first use or long-term shutdown, it is recommended to run without load for 5-10 minutes, confirm that there is no abnormal vibration or noise before loading it for use.
  3. During operation, the exhaust pressure can be adjusted through the control panel to meet the needs of different gas consumption scenarios.

3. Shutdown operation

  1. Before turning off the equipment, switch the load to the no-load state through the control panel to avoid shutdown under pressure.
  2. Press the stop button and the equipment will automatically stop after completing the internal cleaning procedure.
  3. Open the drain valve to drain the compressed air and condensed water in the air storage tank to prevent corrosion of the pipeline.

4. Daily maintenance

  1. Waterway inspection: Regularly confirm that the water supply to the water lubrication system is sufficient and that the water quality cleanliness meets the requirements (it is recommended to use softened water or purified water).
  2. Filter cleaning: Check the air inlet filter every 500 hours to remove surface dust and maintain smooth air circulation.
  3. drainage management: Drain the condensed water from the air storage tank daily or weekly depending on the frequency of use to avoid moisture accumulation and affecting air quality.
  4. Appearance maintenance: Keep the surface of the equipment clean and wipe the heat sinks regularly to ensure heat dissipation efficiency.

5. Safety precautions

  1. Never open the protective cover or touch rotating parts while the equipment is in operation.
  2. During repair or maintenance, it is necessary to cut off the power supply and release the pressure in the air tank.
  3. If abnormal vibration, water leakage or pressure fluctuations are found, stop the machine immediately and contact professional personnel for maintenance.

Through oil-free design and intelligent control system, Granklin water-lubricated single-screw air compressor simplifies the complex oil maintenance process of traditional air compressors. Users only need to pay attention to waterway supply and basic cleaning to achieve efficient and stable compressed air supply. This feature makes it an ideal choice for combining operational convenience and operational reliability in industries such as medicine, food, and electronics that require strict air cleanliness.

Welcome!

Related Articles:
@air
2025-06-18

How to determine equipment gas consumption

How to scientifically determine equipment gas consumption in industrial production and rationally configure air compressors and air supply systems need to be based on accurate equipment gas consumption data. Insufficient gas consumption may lead to reduced production efficiency, while excessive allocation may cause energy waste….

@air
2025-06-30

Will the air compressor break down without stopping?

Impact of long-term continuous operation of air compressors and countermeasures 1. Equipment design characteristics and operating risks Air compressors usually adopt S1 working system (continuous working system) and theoretically have long-term operation capabilities. But long-term continuous operation will accelerate the key…

@air
2025-04-09

How often should precision filter elements be changed?

The replacement cycle of precision filter elements is affected by many factors. The following provides you with a detailed analysis: 1. General replacement criteria Pressure difference method When the pressure difference between the inlet and outlet of the filter reaches the specified threshold (usually 0.07 MPa or the pressure difference meter enters red…

@air
2025-03-05

Why do air compressors need to be maintained for the first time?

The main reasons for the first maintenance of the air compressor are as follows: Ensure the stable operation of the equipment: The first maintenance includes a comprehensive inspection of the overall air compressor, such as appearance, fasteners, wiring, pipelines, etc., aiming to promptly discover and deal with potential problems and prevent small problems from turning […]

@air
2025-03-18

Turn off the air compressor or dryer first

In compressed air systems, the correct shutdown sequence should follow the following principles to ensure equipment safety and system life: recommend shutdown sequence: close the air compressor first reason: The air compressor is an air source. After the system pressure is stopped, the system pressure will gradually decrease to avoid the “idling” of the dryer […]