How to calculate electricity bills for variable frequency and industrial frequency air compressors

To calculate the electricity charges of variable frequency and industrial frequency air compressors, you first need to understand their power consumption, and then calculate them in combination with the local electricity price. The following is a detailed calculation method:

1. Calculation of power consumption

  1. calculation of power consumption of power compressors

    • Formula: Power consumption (kWh) = working time (hours) × Rated power (kW)
    • Example: Suppose a company uses a 75kW industrial frequency compressor and works 24 hours a day.
    • Calculation: Power consumption = 24 hours × 75kW = 1800kWh
  2. Calculation of power consumption of variable frequency air compressors

    • The power consumption of variable frequency air compressors is related to factors such as its operating efficiency, load rate, etc., and the operating efficiency is usually higher than that of industrial frequency air compressors.
    • Formula (approximate): Power consumption (kWh) = working time (hours) × Rated power (kW) × Operating efficiency
    • Example: Assume that the operating efficiency of the inverter air compressor is 80%, the rated power is 75kW, and it works 24 hours a day.
    • calculation: Power consumption = 24 hours × 75kW × 80% = 1440kWh

2. Electricity calculation

  1. Formula: Electricity bill (yuan) = Power consumption (kWh) × Electricity price (yuan/kWh)
  2. Example: Suppose the local electricity price is 0.7 yuan/kWh.
    • Electricity charge for industrial frequency air compressor: 1800kWh × 0.7 yuan/kWh = 1260 yuan/day
    • Electricity charge for variable frequency air compressor: 1440kWh × 0.7 yuan/kWh = 1008 yuan/day

III. Analysis of electricity bill savings

  • Electricity charge saved every day: 1260 yuan – 1008 yuan = 252 yuan
  • Electricity charge saved every year (calculated based on 365 days): 252 yuan/day × 365 days= 92,180 yuan

4. Other considerations

  • Load rate: In actual use, the load rate of the air compressor may be less than 100%, which will affect the power consumption. During calculation, the load rate can be adjusted according to the actual situation.
  • Equipment Efficiency: The efficiency of air compressors of different brands and models may vary. Choosing highly efficient and energy-saving equipment will help reduce electricity bills.
  • Electricity price fluctuations: Electricity prices may fluctuate due to factors such as regions and seasons. The latest electricity price data should be used when calculating.

Summary

Through the above calculations, it can be seen that the frequency converter has significant advantages in electricity bill expenditure compared to the industrial frequency air compressor. In practical applications, enterprises should choose the appropriate type and model of air compressors based on their own needs and budgets to achieve the goal of saving energy and reducing consumption and improving economic benefits. At the same time, strengthening the operation management and maintenance of air compressors will also help reduce energy consumption and extend the service life of the equipment.

Welcome!

Related Articles:
@air
2025-05-29

Introduction of permanent magnet frequency conversion screw air compressor

Technical analysis and industry application of permanent magnet frequency conversion screw air compressor As a high-efficiency power equipment in the industrial field, permanent magnet frequency conversion screw air compressor realizes the supply of compressed air by integrating permanent magnet synchronous motor technology and intelligent frequency conversion control system.

@air
2025-04-23

How often does the air compressor filter change?

The replacement cycle of air compressor filter elements is affected by factors such as working environment, equipment quality, and operating intensity. The specific replacement cycle needs to be comprehensively judged based on actual conditions. The following are professional suggestions and operating guidelines: 1. Air filter element replacement cycle use scenarios…

@air
2025-12-22

How to see how much air the air compressor uses

To accurately understand how much air is used by the air compressor, it is necessary to combine the three methods of direct measurement, indirect calculation and equipment monitoring, and choose the appropriate method according to actual needs. The following are the specific methods and operating steps: 1. Direct measurement method: Install a flowmeter…

@air
2025-02-28

How to Handle Oil-Water Mixture in Compressed Air?

Compressed air systems often produce oil-water mixtures as a byproduct, which can cause equipment damage, reduce efficiency, and lead to environmental issues. Proper treatment is essential to maintain clean and dry air.

@air
2025-08-06

Permanent magnet screw compressor effect

Permanent magnet screw air compressors rely on the efficient characteristics of permanent magnet motors to perform outstanding in terms of energy conservation and stability. Permanent magnet motors generate a stable magnetic field through permanent magnets, which reduces the energy loss during the operation of traditional motors, especially under different load conditions, and can be more accurate…